Protein Storage Buffer

Product#: DCP-PSB1X
$131.71
Availability:
Ships in 24 hours

ISO 13485 Certified Manufacturing

Protein Storage Buffer

A ready-to-use stabilization buffer with glycerol cryoprotection and TCEP-HCl reduction for short- and medium-term storage of purified proteins. A separate 100x broad-spectrum protease inhibitor cocktail (DMSO-based) is included and is intended to be added freshly to the buffer immediately before use, ensuring maximal inhibitor activity at the time of sample storage while preserving a longer shelf life for the base buffer. Includes a separate 100X broad-spectrum protease inhibitor cocktail.

  • Tris base provides a mild, widely compatible environment for many proteins.
  • Glycerol helps prevent aggregation and denaturation during cooling, freezing, and thawing.
  • TCEP-HCl offers a robust, oxidation-resistant reducing agent, avoiding the odor and instability of DTT at this pH.
  • A 100x protease inhibitor cocktail is supplied separately so users can add it to Protein Storage Buffer (or directly to samples) to reach 1x concentration immediately before use.
  • Ultrapure Type 1 water (18.2 MΩ·cm)
  • Customizable formulation available upon request
SKU: DCP-PSB1X | UNSPSC: 12161700 Protein Storage Reagent
FluxMPS™ Protein Storage Buffer
  • pH7.5 for solution A
  • AppearanceClear Solution
  • Filtration0.1µm×2 + 0.04µm×2
  • Storage
  • Shelf Life1 year
ISO 13485:2016 RUO
info This product has two items in it.
Solution A (100 mL)

Protein Storage Buffer (Base)

  • Storage2-8 °C, avoid repeated freeze-thaw cycles
  • Shelf Life1 year
Composition
  • Tris base50 mM
  • Sodium Chloride150 mM
  • Glycerol10%
  • TCEP-HCl2 mM
Solution B (1 mL)

Protease Inhibitor Cocktail (100X) for Solution A

  • Storage-80 °C (long term), avoid repeated freeze-thaw cycles
  • Shelf Life1 year
Composition
  • AEBSF·HCl10 mM
  • Aprotinin80 μM
  • Bestatin5 mM
  • E-64100 μM
  • Leupeptin1 mM
  • Pepstatin A0.1 mM
Why FluxMPS™

Engineered for maximum purity & performance

Standard laboratory reagents filtered at 0.22 µm leave sub-micron particulates, mycoplasma, and aggregates that interfere with sensitive downstream applications. Protein Storage Buffer is manufactured under ISO 13485 quality systems with multi-stage ultra-filtration to eliminate these failure modes.

science

Glycerol cryoprotection

10% glycerol protects proteins from aggregation and denaturation during cooling, freezing at −20 °C, and thawing.

shield

TCEP-HCl reducing agent

2 mM TCEP-HCl maintains a stable, odorless reducing environment that preserves cysteine residues.

water_drop

Tris/NaCl physiological base

50 mM Tris and 150 mM NaCl provide a mild, widely compatible environment for stored proteins.

biotech

Protease inhibitor cocktail

Separate 100X cocktail (AEBSF, Aprotinin, Bestatin, E-64, Leupeptin, Pepstatin A) added fresh for maximum activity.

Purity Architecture

Sequential filtration system

A sequential filtration process reaching 0.1 µm for clean reagent purity exceeding standard 0.22 µm filtration.

  1. 1

    0.1 µm filtration

    Removes large particulates, aggregates, and bacteria. Primary guard providing baseline purity exceeding standard 0.22 µm filtration.

Performance vs. conventional reagents

Standard 0.22 µm single-pass filtration leaves particles in the 0.12–0.22 µm range. FluxMPS™ removes these contaminants for cleaner results and higher reproducibility.

0.1
µm final filter—2.2× finer than 0.22 µm
Diagram of the FluxMPS quadruple-stage filtration system showing four sequential stages: 0.1 μm pre-filtration, 0.04 μm fine filtration, 0.1 μm sterile filtration, and 0.04 μm final polish, engineered for microfluidic organ-on-a-chip cell culture media by Diagnocine
Figure 1. stage sequential filtration architecture (0.1 µm) for ultra-low particulate buffer manufacturing. © Diagnocine® 
Applications

Validated applications

  • Storage of purified recombinant proteins or protein complexes at 4°C (short term) or -20°C (medium term, in aliquots).
  • Storage of concentrated fractions from purification workflows prior to further processing or analysis.
  • Sample stabilization for SDS-PAGE, Western blotting, and analytical assays that tolerate Tris, NaCl, glycerol, TCEP, and protease inhibitors.
Manufacturing

Quality assurance & logistics

verified

ISO 13485:2016 Certified

Manufactured under certified QMS with full traceability and lot documentation.

location_on

Made in USA

All manufacturing, QA testing, and final assembly at DiagnoCine Precision, Totowa, NJ.

Scientific References

Supporting literature

  1. Wingfield PT. Protein precipitation using ammonium sulfate. Curr Protoc Protein Sci. 2001;Appendix 3:Appendix 3F.
  2. Carpenter JF, Manning MC, Randolph TW. Long-term storage of proteins. Curr Protoc Protein Sci. 2002;27(1):4.6.1-4.6.6.
FAQ

Frequently asked questions

Add the 100X cocktail at 1:100 dilution immediately before use. This preserves inhibitor activity during storage.
Minimize freeze-thaw cycles. Aliquot into small volumes before freezing at −20 °C for best results.
TCEP and protease inhibitors may interfere with some enzymatic assays. Desalt or dialyze before assays if needed.
Solution A at 4 °C; Solution B (protease inhibitors) at −80 °C for long-term storage.

Satisfaction
Quality Rating
Value Rating
Style Rating
X