/Content/Upload/Product/Human_ELISA_kits_Diagnocine_1200_1200(127).jpg

Human Estradiol,E2 ELISA Kit

Product#: CS-CSB-E05108h
$522.80
Availability:
Ships in 24 hours

The Ultimate 1-Stop ELISA Marketplace:

60,000+ ELISA kits Available to Serve Scientists from All Fields of Life Science

Always Powered by Diagnocine for Precision Research.

 
Made In-USA · ISO 13485 Certified 

Most comprehensive buffers, reagents and detection agents are provided with each kit to optimize data output.  
All-inclusive format covers everything from sample preparation to signal detection.  Every step can be customized and optimized for your precision research.
DiagnoCine Precision buffers and reagents are Made in USA ISO 13485 Certified

One Stop Purchasing but Zero Compromise on Accuracy

Why waste time searching for your ELISA kit when you can get everything in one place? Diagnocine can provide you with all the ELISA needs you have (customized ELISAs also available) on the planet through a single, streamlined ordering process.  
* all types of species
* HRP and AP detection
* Low target signal enhancement
* Inquire about a trial version or a customized version

Low Signal Optimization Reagents

4 core reagents below are included with every order, plus 1 of the 2 detection-specific reagents (matched automatically to your kit type) — 5 components, every time.

DCP-PIC100X

Protease Inhibitor Cocktail (100X)

Included with every order
 DCP-SM1AbTBS1X

SigMax 1Ab-TBS

Included with every order
 DCP-UTBS1X

Universal Blocking Buffer

Included with every order
 DCP-SM2AbTBS1X

SigMax 2Ab-TBS

Included with every order

+ the 5th component, matched to your kit's detection method:

DCP-HRPTBS1X

HRPQuench-TBS

Exclusively for HRP-based kits
OR
DCP-ALPTBS1X

ALPQuench-TBS

Exclusively for ALP-based kits

If you have any questions or need additional information, please call us at 551-245-1033 or email us at support@diagnocine.com. Our team will be happy to assist you.

Key Value Highlights

Universal Compatibility

All buffers and detection reagents work seamlessly across target proteins, bridging the gap in assay consistency.

1-Stop Convenience

Consolidate your lab's purchasing. Source all ELISA needs and experience optimal buffers and reagents in a single shipment.

Enhanced Precision

Designed by scientists for scientists,  all components are engineered to deliver sharper results and an optical signal.

Human ELISA Kit · Signal Transduction

Human Estradiol,E2 ELISA Kit

Competitive quantitative immunoassay for Human Estradiol,E2 in human serum, plasma.  available in multiple catalog sizes:

Trial 24T 96T

Note: Please send inquiries regarding Trial 24T orders to support@diagnocine.com.

Detection Range
50 pg/ml-1200 pg/ml.
Sensitivity
40 pg/ml.
Assay Time
1-5 hours
Sample Volume
50-100 μL
Product specifications
SpeciesHomo sapiens (Human)
Sample typesserum, plasma.
Detection range50 pg/ml-1200 pg/ml.
Sensitivity40 pg/ml.
Assay time1-5h
Sample loading volume50-100μL
Detection wavelength450 nm
Assay principleCompetitive (Quantitative)
Data analysisStandard curve + Curve Expert software
Research areaSignal Transduction
Storage condition2-8°C (see protocol for full details)
Shipping condition4 °C
Shelf life6 months
Human Estradiol,E2 serum plasma. Signal Transduction Human ELISA
Lead Time

10 business days

Processing + 3-5 days shipping

Availability

In Stock : USA

Worldwide shipping available

Assay principle
Sample prep
Competitive binding
450 nm detection
Standard curve
Quantification

In this competitive ELISA, free Human Estradiol,E2 in the sample competes with plate-bound antigen for antibody binding. Signal intensity is inversely proportional to analyte concentration. Final quantification is derived from a standard curve fitted using Curve Expert software, covering 50 pg/ml-1200 pg/ml. with a minimum detectable dose of 40 pg/ml..

For research use only (RUO). Not intended for diagnostic or therapeutic purposes. Validated in human serum, plasma. matrices only.
Description

The human Estradiol (E2) ELISA kit is a powerful tool for quantitative measurement of estradiol levels in human serum and plasma samples, with a detection range of 50 pg/ml to 1200 pg/ml and a sensitivity of 40 pg/ml. The assay principle is competitive, meaning that two antibodies competitively bind to the estradiol in the sample. The detection is read at a wavelength of 450 nm. The assay time typically ranges from 1 to 5 hours, requiring a sample volume of 50-100 μl. The kit's performance has been validated in multiple studies found in more than 18 publications, ensuring its accuracy and reproducibility in measuring estradiol levels in human samples.

Alternative Names
N/A
Precision

Intra-assay Precision (Precision within an assay): CV%<15%

Three samples of known concentration were tested twenty times on one plate to assess.

Inter-assay Precision (Precision between assays): CV%<15%

Three samples of known concentration were tested in twenty assays to assess.

Typical Data

These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed.

Human Estradiol,E2 ELISA Kit

pg/ml

OD1

OD2

Average

0

1.952

1.834

1.893

50

1.493

1.567

1.530

120

1.045

1.028

1.037

250

0.679

0.629

0.654

500

0.419

0.421

0.420

1200

0.234

0.243

0.239

Materials provided
    • A 96-well Assay plate -- The 96-well plate has been pre-coated with goat-anti-rabbit E2 antibody.
    • Standard 6 x 0.5 ml -- Dilute the standard at dilution series, read the OD values, and then draw a standard curve.
    • Anti-mouse E2 Antibody 1 x 6 ml -- Act as the detection antibody.
    • HRP-conjugate 1 x 6 ml -- Bind to the E2 antibody, and HRP catalyzes the substrate A and B to elicit a chromogenic reaction.
    • Wash Buffer (20 x concentrate) 1 x 15 ml -- Wash away unbound or free substances.
    • Substrate A 1 x 7 ml -- Mix with substrate B, and the TMB is catalyzed by HRP to develop color.
    • Substrate B 1 x 7 ml -- Mix with substrate A, and the TMB is catalyzed by HRP to develop color.
    • Stop Solution 1 x 7 ml -- Stop the color reaction. The solution color immediately turns from blue to yellow.
    • Four Adhesive Strips (For 96 wells)
    • An Instruction manual
Materials not provided
    • A microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 600 nm - 630 nm.
    • An incubator that can provide stable incubation conditions up to 37°C±5°C.
    • Centrifuge
    • Vortex
    • Squirt bottle, manifold dispenser, or automated microplate washer
    • Absorbent paper for blotting the microtiter plate
    • 50-300ul multi-channel micropipette
    • Pipette tips
    • Single-channel micropipette with different ranges
    • 100ml and 500ml graduated cylinders
    • Deionized or distilled water
    • Timer
    • Test tubes for dilution