The Ultimate 1-Stop ELISA Marketplace:
60,000+ ELISA kits Available to Serve Scientists from All Fields of Life Science
Always Powered by Diagnocine for Precision Research.
Most comprehensive buffers, reagents and detection agents are provided with each kit to optimize data output.
All-inclusive format covers everything from sample preparation to signal detection. Every step can be customized and optimized for your precision research.
DiagnoCine Precision buffers and reagents are Made in USA ISO 13485 Certified
Why waste time searching for your ELISA kit when you can get everything in one place? Diagnocine can provide you with all the ELISA needs you have (customized ELISAs also available) on the planet through a single, streamlined ordering process.
* all types of species
* HRP and AP detection
* Low target signal enhancement
* Inquire about a trial version or a customized version
4 core reagents below are included with every order, plus 1 of the 2 detection-specific reagents (matched automatically to your kit type) — 5 components, every time.
+ the 5th component, matched to your kit's detection method:
If you have any questions or need additional information, please call us at 551-245-1033 or email us at support@diagnocine.com. Our team will be happy to assist you.
Universal Compatibility
All buffers and detection reagents work seamlessly across target proteins, bridging the gap in assay consistency.
1-Stop Convenience
Consolidate your lab's purchasing. Source all ELISA needs and experience optimal buffers and reagents in a single shipment.
Enhanced Precision
Designed by scientists for scientists, all components are engineered to deliver sharper results and an optical signal.
Human Estradiol,E2 ELISA Kit
Competitive quantitative immunoassay for Human Estradiol,E2 in human serum, plasma. available in multiple catalog sizes:
Note: Please send inquiries regarding Trial 24T orders to support@diagnocine.com.
| Species | Homo sapiens (Human) |
| Sample types | serum, plasma. |
| Detection range | 50 pg/ml-1200 pg/ml. |
| Sensitivity | 40 pg/ml. |
| Assay time | 1-5h |
| Sample loading volume | 50-100μL |
| Detection wavelength | 450 nm |
| Assay principle | Competitive (Quantitative) |
| Data analysis | Standard curve + Curve Expert software |
| Research area | Signal Transduction |
| Storage condition | 2-8°C (see protocol for full details) |
| Shipping condition | 4 °C |
| Shelf life | 6 months |
10 business days
Processing + 3-5 days shipping
In Stock : USA
Worldwide shipping available
Competitive binding
450 nm detection
Standard curve
Quantification
In this competitive ELISA, free Human Estradiol,E2 in the sample competes with plate-bound antigen for antibody binding. Signal intensity is inversely proportional to analyte concentration. Final quantification is derived from a standard curve fitted using Curve Expert software, covering 50 pg/ml-1200 pg/ml. with a minimum detectable dose of 40 pg/ml..
The human Estradiol (E2) ELISA kit is a powerful tool for quantitative measurement of estradiol levels in human serum and plasma samples, with a detection range of 50 pg/ml to 1200 pg/ml and a sensitivity of 40 pg/ml. The assay principle is competitive, meaning that two antibodies competitively bind to the estradiol in the sample. The detection is read at a wavelength of 450 nm. The assay time typically ranges from 1 to 5 hours, requiring a sample volume of 50-100 μl. The kit's performance has been validated in multiple studies found in more than 18 publications, ensuring its accuracy and reproducibility in measuring estradiol levels in human samples.
Intra-assay Precision (Precision within an assay): CV%<15% | ||||||
Three samples of known concentration were tested twenty times on one plate to assess. | ||||||
Inter-assay Precision (Precision between assays): CV%<15% | ||||||
Three samples of known concentration were tested in twenty assays to assess. | ||||||
These standard curves are provided for demonstration only. A standard curve should be generated for each set of samples assayed. | |||||||
| |||||||
pg/ml | OD1 | OD2 | Average | ||||
0 | 1.952 | 1.834 | 1.893 | ||||
50 | 1.493 | 1.567 | 1.530 | ||||
120 | 1.045 | 1.028 | 1.037 | ||||
250 | 0.679 | 0.629 | 0.654 | ||||
500 | 0.419 | 0.421 | 0.420 | ||||
1200 | 0.234 | 0.243 | 0.239 | ||||
- A 96-well Assay plate -- The 96-well plate has been pre-coated with goat-anti-rabbit E2 antibody.
- Standard 6 x 0.5 ml -- Dilute the standard at dilution series, read the OD values, and then draw a standard curve.
- Anti-mouse E2 Antibody 1 x 6 ml -- Act as the detection antibody.
- HRP-conjugate 1 x 6 ml -- Bind to the E2 antibody, and HRP catalyzes the substrate A and B to elicit a chromogenic reaction.
- Wash Buffer (20 x concentrate) 1 x 15 ml -- Wash away unbound or free substances.
- Substrate A 1 x 7 ml -- Mix with substrate B, and the TMB is catalyzed by HRP to develop color.
- Substrate B 1 x 7 ml -- Mix with substrate A, and the TMB is catalyzed by HRP to develop color.
- Stop Solution 1 x 7 ml -- Stop the color reaction. The solution color immediately turns from blue to yellow.
- Four Adhesive Strips (For 96 wells)
- An Instruction manual
- A microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 600 nm - 630 nm.
- An incubator that can provide stable incubation conditions up to 37°C±5°C.
- Centrifuge
- Vortex
- Squirt bottle, manifold dispenser, or automated microplate washer
- Absorbent paper for blotting the microtiter plate
- 50-300ul multi-channel micropipette
- Pipette tips
- Single-channel micropipette with different ranges
- 100ml and 500ml graduated cylinders
- Deionized or distilled water
- Timer
- Test tubes for dilution
Human Estradiol,E2 ELISA Kit | For research use only | Store 2-8°C | Diagnocine